CBXLD - FLOWCOAT PRIMER THINNER, TL 58
- MSDS: CBXLD
- Manufacturer: AKZO COATINGS INC
- Product Name: FLOWCOAT PRIMER THINNER, TL 58
- National Stock Number: 8010-00N071637
Product Identification
Product ID:FLOWCOAT PRIMER THINNER, TL 58
MSDS Date:09/02/1987
FSC:8010
NIIN:00N071637
MSDS Number: CBXLD
Responsible Party
ORANGE, CA 92665
US
Emergency Phone: 313-637-0400
Info Phone: 313-855-7313
Preparer: CHARLES L GRUBBS
Cage: 98502
Contractor
Telephone: 714-637-1750; CHEMTREC 800-424-9300
Cage: 98502
Ingredients
ACETIC ACID, BUTYL ESTER; (BUTYL ACETATE ESTER SOLVENT)
CAS: 123-86-4
RTECS: AF7350000
Fraction By Weight: 25-40%
OSHA PEL 150 PPM
ACGIH TLV: 150 PPM/200STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
BUTYL ALCOHOL; (N-BUTYL ALCOHOL) (SARA 313) (CERCLA) VP
CAS: 71-36-3
RTECS: EO1400000
Fraction By Weight: 10-25%
OSHA PEL 100 PPM
ACGIH TLV: C 50 PPM, S
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
3.3
CAS: 108-94-1
RTECS: GW1050000
Fraction By Weight: 5-20%
OSHA PEL 50 PPM, S
ACGIH TLV: 25 PPM, S
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
2-PENTANONE, 4-METHYL-; (METHYL ISOBUTYL KETONE) (MIBK)
CAS: 108-10-1
RTECS: SA9275000
Fraction By Weight: 30-45%
OSHA PEL 100 PPM
ACGIH TLV: 50 PPM/75 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
9.5
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 20-35%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM/150STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
INHALING CONTENTS MAY BE HARMFUL/FATAL. RPTS HAVE
RTECS: 9999999ZZ
OVEREXP HAS BEEN
RTECS: 9999999ZZ
HAVE SHOWN THAT MANY PETRO HYDROCARBONS POSE
RTECS: 9999999ZZ
AS A PREC, EXPOS TO LIQS & VAPS OF PETRO PRODS
RTECS: 9999999ZZ
KIDNEY DMG. OVEREXP TO MATL HAS BEEN SUGGESTED AS
RTECS: 9999999ZZ
OVEREXPOSURE MAY CAUSE RED BLOOD CELL & LEUCOCYTE
RTECS: 9999999ZZ
CUT EMPTY DRUM. DO NOT HANDLE UNTIL MFR'S
RTECS: 9999999ZZ
HEATING. REMOVE DECOMP PRODS FORMED DURING
RTECS: 9999999ZZ
NEEDED TO AVOID RPTD/FREQUENT SKIN CONT.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THE FOLLOWING HAZ HAVE BEEN REPORTED
TO BE ASSOC W/INDIVIDUAL COMPONENTS OF THIS PROD. THESE HAZ MAY NOT
ALL BE ASSOC W/FINISHED PROD. ACUTE: EXCESS INHAL OF VAPS CAN CAUSE
NASAL & UPPER RESP TRACT IR RIT, DIZZ, WEAK, FATG, NAUS, HDCH,
POSSUNCON, & EVEN ASPHY. EYES: MAY CAUSE SEV IRRIT, REDNESS, (EFTS
OF OVEREXPOSURE)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: TEARING, BLURRED VISION, & SENSATION
OF SEEING HALOS AROUND LIGHTS. MAY CAUSE BURNS/CORNEAL INJURY.
PRLNG CONT W/SKIN MAY LEAD TO EXTRACTION OF NATRL OILS W/RSLT MILD
IRRIT. MAY CAUSE BURNS. CAN BE ABSORBED THRU SKIN. PRLNG/RPTD CONT
MAY CAUSE DERM. INGEST: CAN CAUSE GI IRRIT, NAUS, VOMIT, & DIARR.
(SUP DAT)
Medical Cond Aggravated by Exposure:NONE EXPECTED.
First Aid
First Aid:INHALATION: MOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION IF
NECESSARY. SKIN: WASH WITH SOAP AND WATER. EYES: FLUSH WITH WATER
FOR AT LEAST 15 MINUTES, CONSULT MD. INGESTION: DRINK ONE OR TWO
GLASSES OF WATER TO DILUTE. DO NOT INDUCE VOMITING. CONSULT MD OR
POISON CONTROL CENTER IMMEDIATELY. TREAT SYMPTOMATICALLY.
Fire Fighting
Flash Point Method:TCC
Flash Point:62.0F,16.7C
Lower Limits:1.0%
Extinguishing Media:USE FOAM, CARBON DIOXIDE, DRY CHEMICALS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . WATER MAY BE INEFFECTIVE. WATER SHOULD BE
USED TO COOL CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, SPARKS, ELEC EQUIP & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICATION TO HOT (SUP DAT)
Accidental Release
Spill Release Procedures:REFER TO PROTECTIVE MEASURES SECTIONS. REMOVE
ALL SOURCES OF IGNITION. AVOID BREATHING VAPORS. VENTILATE AREA.
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE CONTRS OUT OF SUN & AWAY FROM
HEAT, SPARKS & OPEN FLAMES. CLOSE CONTRS AFTER EACH USE. CONSULT
NFPA CODE FOR ADDITIONAL STORAGE REQUIREMENTS.
Other Precautions:DO NOT TAKE INTERNALLY. USE APPRVD BONDING &
GROUNDING PROC. OBSERVE LABEL PREC. KEEP CLOSURES TIGHT & CONTR
UPRIGHT TO PVNT LEAKAGE. NEVER USE PRESS TO EMPTY-DRUM IS NOT A
PRESS VESSEL. AVOID BRTHG S ANDING DUST. DO NOT WELD/FLAME (ING 12)
Exposure Controls
Respiratory Protection:ADEQUATE VENTILATION IS REQUIRED. USE NIOSH/MSHA
APPROVED RESPIRATOR DEVICE. SEE YOUR SAFETY EQUIPMENT SUPPLIER FOR
EVALUATION AND RECOMMENDATION. IN CONFINED AREAS USE NIOSH/MSHA
APPROVED AIRLINE RES PIRATOR OR HOOD.
Ventilation:PROVIDE SUFFICIENT VENT TO KEEP VAP CONC BELOW GIVEN TLV &
LEL. FOR BAKING FINISHES, EXHST VAP EMITTED ON (ING 13)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMER EYEWASH & DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA . USE CHEM RESIST APRON, BOOTS/OTHER CLTHG IF (ING
14)
Work Hygienic Practices:WASH HANDS BEFORE EATING, SMOKING OR USING
WASHROOM.
Supplemental Safety and Health
EXPLO HAZ: SURF REQS SPEC PREC. DURING EMER CNDTNS OVEREXP TO DECOMP
PROD MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT, OBTAIN
MED ATTN. EFTS OF OVEREXP: ASPIR OF MATL INTO LUNGS CAN CAUSE CHEM
PNEUMIT WHICH CAN BE FATAL. IRRIT & DEPRESSANT FOR CNS. NOTICE:
INTENTIONAL MISUSE BY DELIBERATELY CONCG & (ING 6)
Chemical Properties
Boiling Pt:B.P. Text:>241F,>116C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.875
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SMOKE, OXIDES OF NITROGEN.
Disposal
Waste Disposal Methods:INCINERATE IN AN APPROVED FACILITY, DO NOT
INCINERATE CLOSED CONTAINERS. DISPOSE OF IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL POLLUTION CONTROL REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.